EN
NSQ Series Cast Basalt Wear-Resistant Three-Way Ball Diverter Valves
NSQ Series Cast Basalt Wear-Resistant Three-Way Ball Diverter Valves

NSQ Series Cast Basalt Wear-Resistant Three-Way Ball Diverter Valves

Developed from the NQ series cast basalt wear-resistant ball valve, this three-way diverter valve is used to change pumps, switch pipelines and redirect flow. The source describes wear and corrosion resistance, easy operation and tight sealing, and reports long-term use in thermal power and petrochemical installations with service life exceeding that of other valves by more than twenty times.
Product Details

NSQ Series Cast Basalt Wear-Resistant Three-Way Ball Diverter Valves technical drawing

 

Applications and specifications

Developed from the NQ series cast basalt wear-resistant ball valve, this three-way diverter valve is used to change pumps, switch pipelines and redirect flow. The source describes wear and corrosion resistance, easy operation and tight sealing, and reports long-term use in thermal power and petrochemical installations with service life exceeding that of other valves by more than twenty times.

 

Main performance specifications

Nominal diameter DN (mm)

100-500

Nominal pressure PN (MPa)

1.0-6.4

Service media

Slurry, ash/slag slurry, crude oil, oil, water and steam

Operating temperature

-40-120、-40-250

Actuation

Electric

 

Main component materials

Component

Material

Body and bonnet

WCB

Ball

WCB+1Cr18Ni9Ti

Flow passage

Cast basalt

Stem

40Cr

Sealing ring

Polytetrahydrofuran polyether, fluororubber

 

Outline and main dimensions

Dimensions (mm)

L

H

H1

D

k

D1

D2

C

f

Z-Φd

Nominal diameter DN (mm)

Pressure (MPa)

1

100

616

600

150

220

180

156

300

21

3

8-Φ18

125

616

614

160

250

210

184

320

21

3

8-Φ18

150

616

629

176

285

240

211

352

21

3

8-Φ22

200

685

699

214

340

295

266

428

25

3

8-Φ22

250

685

729

244

395

350

319

488

25

3

12-Φ22

300

685

759

277

445

400

370

554

29

4

12-Φ22

350

855

875

325

505

460

429

650

29

4

16-Φ22

400

855

915

365

565

515

480

730

34

4

16-Φ26

450

855

964

402

615

565

530

804

34

4

20-Φ26

500

855

1004

443

670

620

582

885

39

4

20-Φ26

1.6

100

616

600

150

220

180

156

300

21

3

8-Φ18

125

616

614

160

250

210

184

320

21

3

8-Φ18

150

616

629

176

285

240

211

352

21

3

8-Φ22

200

685

699

214

340

295

266

428

25

3

12-Φ22

250

685

729

244

405

355

319

488

25

3

12-Φ26

300

685

759

277

460

410

370

554

29

4

12-Φ26

350

855

875

325

520

470

429

650

29

4

16-Φ26

400

855

915

365

580

525

480

730

34

4

16-Φ30

450

855

964

402

640

585

548

804

34

4

20-Φ30

500

855

1004

443

715

650

609

885

39

4

20-Φ33

2.5 

100

616

600

150

235

190

156

300

22

3

8-Φ22

125

616

614

160

270

220

184

320

22

3

8-Φ26

150

616

629

176

300

250

211

352

24

3

8-Φ26

200

685

699

214

360

310

274

428

25

3

12-Φ26

250

685

729

244

425

370

330

488

28

3

12-Φ30

300

685

759

277

485

430

389

554

32

4

16-Φ30

350

855

875

325

555

490

448

650

35

4

16-Φ33

400

855

915

365

620

550

503

730

38

4

16-Φ36

450

855

964

402

670

600

548

804

38

4

20-Φ36

500

855

1004

443

730

660

609

885

42

4

20-Φ36

gen products deco l
gen products deco r
icon Related News icon

Related News

Cast Basalt in Chemical-Service Linings: A Selection Checklist

Assess chemical exposure, abrasion, temperature and the bedding and joint system when considering cast basalt for floors or process linings.
Read More

Planning Cast Basalt Linings for Ash and Slag Conveying

Review ash and slag conveying conditions, fitting geometry and connection interfaces before selecting a cast basalt lined pipeline.
Read More

Cast Basalt Tile Shapes and Lining Layout: What to Specify

Choose cast basalt tile geometry by matching the equipment surface, joint arrangement and installation plan to the actual wear location.
Read More

Planning a Cast Basalt Chute Lining Retrofit in a Coal Washing Plant

Plan a coal washing chute retrofit around the wear location, liner dimensions, installation details and the requirements of the operating plant.
Read More

Cast Basalt Pipe and Lined Steel Pipe: Choosing a Configuration

Understand the roles of cast basalt pipe and cast basalt lined steel pipe when planning wear-resistant slurry and tailings conveying systems.
Read More

How to Select Cast Basalt Linings for Industrial Wear Protection

Select cast basalt tiles, pipes or lined steel pipe by reviewing the conveyed material, equipment geometry and installation requirements.
Read More
icon service icon
Related service
icon gear t

Wear Life & Installation Planning

Practical guidance for assessing wear conditions, planning cast basalt lining layouts and preparing installation details for chutes, hoppers and pipelines.

icon gear t

Offer Customized Services

Technical specialists help select cast basalt dimensions and configurations for your chutes, silos and pipelines, with installation guidance.

icon hex t

Foreign Trade Project Support

From inquiry and samples to inspection, export documents and sea shipment, our team supports overseas cast basalt material procurement.

icon Resist Wear & Corrosion, Forge Long-term Stability icon

Cast Basalt Wear-Resistant Products

    Products
    Contacts
    WhatsApp
    Email